Suggestions

Electrolysis System CHLORINSITU III

Output 100 – 10,000 g/h of chlorine

Ultra-pure or low-chloride and low-chlorate sodium hypochlorite requires specialist plant engineering. The electrolysis system CHLORINSITU III is the solution for you.

Product description

Chlorine and sodium hydroxide made from common salt. Directly on-site.

Electrolysis Chlorine and sodium hydroxide are produced in-situ in electrolysis by passing an electric ... more in the glossary systems of type CHLORINSITU III generate sodium hypochlorite with a concentration of approximately 25 g/l with minimal entrainment of sodium chloride (85 % yield) from the membrane cell into the finished product. The final sodium hypochlorite solution can be metered, as required, by separate metering pumps. Due to its moderate pH value The pH value is a measure of the acidic or basic character of an aqueous solution. more in the glossary of 9.5 – 10, it affects the pH of the treated water significantly less than if conventional sodium hypochlorite (pH 12 – 13.5) were used. Less acid is therefore used to adjust the pH value The pH value is a measure of the acidic or basic character of an aqueous solution. more in the glossary, enabling savings of up to 70 %.

Your benefits

  • Sodium hypochlorite solution low in chloride and chlorate with a high chlorine concentration (25 g/l free chlorine)
  • Minimal acid consumption for pH correction, enabling savings of up to 70 %
  • Safe system control with remote diagnosis by Remote Control Engineer
  • Excellent service life of the membrane cells thanks to a constant vacuum
  • A frequency-controlled centrifugal pump maintains the vacuum constant in the enclosed anode area
  • Excellent operating safety due to its design as a negative pressure system

Technical Details

  • Modern PLC with large illuminated display
  • Integrated Remote Control Engineer for remote diagnosis and troubleshooting
  • Storage tank for multiple points of injection

Technical Data

Power supply 3 x 400 V (VAC/3P/N/PE/50 Hz)

Type/output

Fuse

Power uptake

Salt consumption

Max. consumption of process water

Max. consumption of cooling water

Dimensions L x W x H

Brine tank

Recommended capacity storage tank

g/h

A

kW

kg/d

l/h

l/h

mm

l

l

100

3 x 16

1.10

5

4

80

1,250 x 600 x 1,550

210

200

200

3 x 16

1.50

10

8

80

1,250 x 600 x 1,550

210

300

300

3 x 16

1.90

15

12

100

1,250 x 600 x 1,550

210

400

400

3 x 16

2.30

20

16

100

1,250 x 600 x 1,550

210

500

500

3 x 16

2.70

25

20

125

1,250 x 600 x 1,550

210

600

600

3 x 20

3.10

30

24

125

1,650 x 600 x 2,000

400

700

750

3 x 25

3.70

35

30

150

1,650 x 600 x 2,000

400

800

1000

3 x 25

4.70

50

40

150

1,650 x 600 x 2,000

400

1200

1250

3 x 35

5.70

60

50

150

1,650 x 600 x 2,000

400

1500

1500

3 x 35

6.70

70

60

180

1,650 x 600 x 2,000

400

1700

1750

3 x 35

7.70

80

70

180

1,650 x 600 x 2,000

400

2000

2000

3 x 50

8.70

100

80

200

1,750 x 1,200 x 2,000

520

2200

2500

3 x 63

10.70

125

100

250

1,750 x 1,200 x 2,000

520

3000

3000

3 x 63

12.70

150

120

300

1,750 x 1,200 x 2,000

520

3300

3500

3 x 80

14.70

175

140

350

1,750 x 1,200 x 2,000

520

4000

5000

3 x 90

20.70

250

200

500

3,100 x 1,800 x 2,070

1,150

5800

7000

3 x 100

29.40

350

280

700

3,100 x 1,800 x 2,070

1,150

6000

8500

3 x 130

35.70

425

340

850

4,300 x 1,800 x 2,070

1,150

7500

10000

3 x 160

40.70

500

400

1000

4,300 x 1,800 x 2,070

1,150

11000

Scope of delivery

Electrolysis systems of type CHLORINSITU III are mounted ready-wired on a powder-coated stainless steel frame with a controller (PLC) in the control cabinet. They include a Remote Control Engineer for remote diagnosis and troubleshooting, integrated water softener system, membrane electrolysis cells, hydrogen bleed system and separate salt dissolving tanks with level monitoring unit. Dynamic level control to monitor the storage tank for sodium hypochlorite to be provided on-site. A chlorine gas detector and automatic monitoring of water hardness downstream of the softening system come as standard with systems producing more than 600 g/h.

Remark

Electrolysis systems of type CHLORINSITU II, III, V and V Plus are available and planned to meet customer specifications. This is true both for the system documentation and the subsequent supply of spare parts and maintenance.

Downloads for Electrolysis System CHLORINSITU III

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by Document type
Load more matches ...
No more matches available!

Unfortunately, we did not find an appropriate match.

All words written correctly?
Search again with fewer or different search terms?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

Chlorine and sodium hydroxide made from common salt. Directly on-site.

Electrolysis Chlorine and sodium hydroxide are produced in-situ in electrolysis by passing an electric ... more in the glossary systems of type CHLORINSITU III generate sodium hypochlorite with a concentration of approximately 25 g/l with minimal entrainment of sodium chloride (85 % yield) from the membrane cell into the finished product. The final sodium hypochlorite solution can be metered, as required, by separate metering pumps. Due to its moderate pH value The pH value is a measure of the acidic or basic character of an aqueous solution. more in the glossary of 9.5 – 10, it affects the pH of the treated water significantly less than if conventional sodium hypochlorite (pH 12 – 13.5) were used. Less acid is therefore used to adjust the pH value The pH value is a measure of the acidic or basic character of an aqueous solution. more in the glossary, enabling savings of up to 70 %.

Your benefits

  • Sodium hypochlorite solution low in chloride and chlorate with a high chlorine concentration (25 g/l free chlorine)
  • Minimal acid consumption for pH correction, enabling savings of up to 70 %
  • Safe system control with remote diagnosis by Remote Control Engineer
  • Excellent service life of the membrane cells thanks to a constant vacuum
  • A frequency-controlled centrifugal pump maintains the vacuum constant in the enclosed anode area
  • Excellent operating safety due to its design as a negative pressure system

Application

Technical Data

Downloads

Contact us

»We are always available to help. Don't hesitate to contact us.«

+64 98376075  Send request   

Matching Products

As a controller in water analysis, the DULCOMETER Compact is the correct controller for control tasks that require only a 1-way control.

more

Do you wish for a simple controller for water analysis? One that is easy to operate and with which you can freely select between all common measured variables per channel? There is one: our all-rounder DULCOMETER diaLog DACb! What is more, it is Ethernet-/LAN-capable and can be ideally integrated into existing networks.

more

The measuring and control system DULCOMARIN 3 is your digital link to the technology of the future. It controls the entire range of swimming pools – from adventure pools to private pools – and is used as a multi-pool system for up to 16 filter circuits.

more

The application-based DULCOTEST sensors for free chlorine deliver precise measured values and a high degree of monitoring and process reliability in any disinfection application.

more

Reliably measure total chlorine with the versatile DULCOTEST sensors for total chlorine. Accurate measured values and a high degree of monitoring and process reliability are guaranteed.

more