Chlorine Dioxide System Bello Zon CDKd

7.5 – 12,000 g/h chlorine dioxide. Maximum volume of water that can be treated with metering of 0.2 ppm ClO2, depending on the size of the system: 60,000 m3/h

Chlorine dioxide system for the metering of chlorine dioxide with concentrated starting chemicals. The proven safety concept protects people and the environment. The certified yield guarantees efficient chlorine dioxide production. Bello Zon CDKd can be easily and safely integrated into any water treatment process.

Product description

Chlorine dioxide system Bello Zon CDKd treats medium to large volumes of water with concentrated chemicals.

In the chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system there is an intrinsically safe pre-dilution station for concentrated hydrochloric acid. The consumption of hydrochloric acid can therefore be automatically adapted on-site to the individual operating conditions by means of a patent-pending process.

The system control offers impressive and user-friendly menu navigation and ensures the precise production of chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary. The chemicals are mixed perfectly in a reactor made of food-safe PVDF. You thereby benefit from maximum yield with the lowest possible consumption of chemicals and maximum operating safety. The requirements set by the Industry 4.0 standards of tomorrow are met thanks to communication via popular bus systems and our DULCONNEX Platform.

The construction and operating mode of the system also complies with all requirements of DVGW specifications W 224 and W 624 and the system is intended for operation with concentrated chemicals Bello Zon chlorite (24.5% NaClO2) and acid (25 – 37% HCl). The liquid levels of the starting chemicals can either be displayed and monitored by external liquid level sensors or by adaptive liquid level monitoring for which a patent has been applied.

Your benefits

  • Cost savings through optimised acid consumption
  • Communication interfaces via bus systems and DULCONNEX
  • Monitoring of starting feed chemical tanks thanks to precise level indicators
  • Consumption levels can be planned, enhanced availability and economical operation thanks to verification of chlorine dioxide metering and system output
  • Configurable alarms and automatically generated reports: For simplified compliance with documentation obligations and to demonstrate correct operation
  • Remote monitoring of systems in potentially dangerous environments

Field of application

The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.

  • Municipal drinking water and wastewater treatment
  • Industrial process and cooling water

    Technical Details

    Power supply

    • 100-230 V, 50/60 Hz

    Inputs

    • 4 analogue inputs (0/4-20 mA)
      • Water flow
      • Control variable
      • Acid level
      • Chlorite level
    • 4 digital inputs
      • Contact water meter 0.25-20 Hz
      • Pause
      • Alternative metering
      • External fault

    Outputs

    • 1 operating signal relay
    • 1 alarm signal relay
    • 1 warning signal relay
    • Mains output for control of the bypass pump
    • 2 freely configurable analogue outputs (0/4-20 mA)

    Operating substances

    • 24.5% sodium chlorite, purity according to EN 938
    • 25-37 % hydrochloric acid, purity according to EN 939
    • Particle-free water

    Degree of protection

    • IP 65

    Bus communication options

    • Modbus TCP
    • Modbus RTU
    • Profibus
    • Profinet
    • DULCONNEX

    Technical Data

    Type

    Chlorine dioxide metering rate (min.…max./hour, min./day)*

    Max. operating pressure**

    Operating temperature

    Suction-side connector dimension of calibration vessels

    Dimensions of the bypass connector

    g/h

    g/d

    bar

    °C

    Chlorite

    Acid

    DN

    * The metering figures relate to 5 or 2 bar back pressure and an ambient temperature of 20 °C. The minimum capacity/hour is based on the fact that when the system is operating at below 5 % of the nominal capacity, continuous metering is no longer possible due to the fact that the metering pumps then have a low pumping frequency. The reactor contents should be changed at least twice daily with systems that do not work continuously. Therefore, do not operate the system below the stated minimum capacity/day.

    ** at an ambient temperature of 35 °C

    CDKd 150

    7.5…150

    56

    8

    10…40

    8x5

    6x4

    25

    CDKd 400

    20…400

    140

    8

    10…40

    12x9

    8x5

    25

    CDKd 900

    45…900

    300

    8

    10…40

    Pressure hose nozzle d16

    8x5

    25

    CDKd 2000

    100…2,000

    700

    5

    10…40

    Pressure hose nozzle d20

    12x9

    40

    CDKd 2800

    140…2,800

    700

    5

    15…40

    Pressure hose nozzle d20

    12x9

    40

    CDKd 7300

    370…7,300

    1750

    3

    15…40

    Pressure hose nozzle d32

    Pressure hose nozzle d16

    40

    CDKd 12000

    600…12,000

    1750

    2

    18…40

    Pressure hose nozzle d32

    Pressure hose nozzle d16

    40

    Type

    Dimensions H x W x D (approx.)*

    Weight

    Supply voltage 230 V**

    Supply voltage 115 V**

    Power consumption without bypass pump

    Power consumption with bypass pump

    HCl (30 %)***

    NaClO2 (24.5 %)***

    mm

    kg

    A

    A

    W

    W

    l/h

    l/h

    * including main system, pre-dilution and rinse valve, without bypass pump and water feed section

    ** 230 V figures with bypass pump, 115 V figures without bypass pump

    *** Sodium chlorite (NaClO2) 24.5 %, purity in accordance with EN 938, hydrochloric acid 25-36%, purity in accordance with EN 939. The chemical consumption may vary depending on the temperature. The hydrochloric acid consumption is calculated for a concentration of 30%. Up to 25% hydrochloric acid can be saved with the aid of automatic acid adjustment.

    CDKd 150

    1,300 x 1,000 x 250

    89

    3.9

    1.7

    110

    640

    0.9

    0.9

    CDKd 400

    1,675 x 900 x 460

    119

    3.9

    1.8

    160

    690

    2.5

    2.5

    CDKd 900

    1,920 x 920 x 520

    131

    4.2

    2.3

    210

    740

    5.6

    5.6

    CDKd 2000

    1,880 x 1,320 x 570

    201

    -

    3.7

    370

    -

    12.3

    12.3

    CDKd 2800

    1,880 x 1,320 x 570

    201

    -

    3.7

    370

    -

    17.3

    17.3

    CDKd 7300

    2,250 x 1,850 x 500

    216

    -

    8.6

    610

    -

    45.1

    45.1

    CDKd 12000

    2,250 x 1,850 x 500

    216

    -

    8.6

    610

    -

    74.1

    74.1

    Ambient conditions:

    Permissible relative air humidity (non-condensing)max. 85% rel.
    Permissible ambient temperature40 °C
    Permissible temperature of chemicals10 … 35 °C
    Storage and transport temperature-10 … +40 °C
    Degree of protectionIP 65

    Downloads for Chlorine Dioxide System Bello Zon CDKd

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by Document type
    Load more matches ...
    No more matches available!

    Unfortunately, we did not find an appropriate match.

    All words written correctly?
    Search again with fewer or different search terms?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    Chlorine dioxide system Bello Zon CDKd treats medium to large volumes of water with concentrated chemicals.

    In the chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system there is an intrinsically safe pre-dilution station for concentrated hydrochloric acid. The consumption of hydrochloric acid can therefore be automatically adapted on-site to the individual operating conditions by means of a patent-pending process.

    The system control offers impressive and user-friendly menu navigation and ensures the precise production of chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary. The chemicals are mixed perfectly in a reactor made of food-safe PVDF. You thereby benefit from maximum yield with the lowest possible consumption of chemicals and maximum operating safety. The requirements set by the Industry 4.0 standards of tomorrow are met thanks to communication via popular bus systems and our DULCONNEX Platform.

    The construction and operating mode of the system also complies with all requirements of DVGW specifications W 224 and W 624 and the system is intended for operation with concentrated chemicals Bello Zon chlorite (24.5% NaClO2) and acid (25 – 37% HCl). The liquid levels of the starting chemicals can either be displayed and monitored by external liquid level sensors or by adaptive liquid level monitoring for which a patent has been applied.

    Your benefits

    • Cost savings through optimised acid consumption
    • Communication interfaces via bus systems and DULCONNEX
    • Monitoring of starting feed chemical tanks thanks to precise level indicators
    • Consumption levels can be planned, enhanced availability and economical operation thanks to verification of chlorine dioxide metering and system output
    • Configurable alarms and automatically generated reports: For simplified compliance with documentation obligations and to demonstrate correct operation
    • Remote monitoring of systems in potentially dangerous environments

    Application

    Technical Data

    Downloads

    Contact us

    »We are always available to help. Don't hesitate to contact us.«

    +64 98376075  Send request   

    Matching Products

    The controller DULCOMETER D1Cb/D1Cc can be used for control tasks in potable water treatment, wastewater treatment and many other areas. Safe, convenient and clear, thanks to the large illuminated graphic display, plain text operating menu and pH sensor monitoring.

    more

    Do you wish for a simple controller for water analysis? One that is easy to operate and with which you can freely select between all common measured variables per channel? There is one: our all-rounder DULCOMETER diaLog DACb! What is more, it is Ethernet-/LAN-capable and can be ideally integrated into existing networks.

    more

    The metering system DULCODOS universal combines carefully selected standard components with the solenoid-driven metering pump you have selected. This is your convenient method for the reliable metering of liquid chemicals – and is available cost-effectively and extremely quickly thanks to the preconfigured modules.

    more

    The DULCONNEX Gateway safely and reliably transfers the data of all products supported as standard to the DULCONNEX Cloud

    more

    ORP measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real-time. Can be used in water treatment or industrial process waters with strict requirements.

    more

    Chlorite measurements with DULCOTEST sensors in disinfection processes involving chlorine dioxide – high process reliability guaranteed.

    more

    Chlorine dioxide measurement with DULCOTEST sensors offers precise, reliable, application-specific measured values in real-time for all oxidation and disinfection tasks.

    more